July 31, 2026
On July 30, 2026 at 11:33 PM CT, the KeeperPAM connection routing service in the EU region started throwing errors. The Router/Gateway errors lasted approximately 12 hours and 45 minutes, with full service restored at approximately 12:18 PM CT on July 31. During this window, the main Keeper EU platform (vault access, authentication, and all other Keeper services) remained fully operational throughout.
On July 22, a routine deployment to our connection routing service (“Keeper Router”) included an updated dependency that changed how the service retrieves its startup configuration. A misconfiguration in the endpoint caused EU region to look for a FIPS endpoints, which are not available. As a result, when service containers in the EU region restarted following the deployment, they were unable to retrieve their startup configuration and entered a failed state.
Two factors allowed this failure to go undetected for over a week. First, existing containers continued serving traffic while replacement containers silently failed to start, so there was no immediate customer impact from the July 22 deployment. QA also passed all production verification tests. Second, the configuration-load failure was logged at INFO level rather than ERROR or CRITICAL, so no PagerDuty alerts were generated.
On the night of July 30, the last healthy containers cycled out, the service's load balancer had zero healthy targets, and the endpoint began returning HTTP 503 errors. Automated health-check monitoring detected the outage within seconds and paged our on-call team.
We apologize to our EU customers for the disruption.